airvo 2 manual

The AIRVO 2 Manual provides comprehensive guidance for healthcare professionals on using the device, ensuring safe and effective high-flow nasal therapy delivery.

It covers setup, operation, and maintenance, tailored for treating spontaneously breathing patients and transitioning them from complex ventilation systems.

Overview of the AIRVO 2 Device

The AIRVO 2 is a high-flow nasal therapy device designed for healthcare professionals to deliver warmed, humidified air to patients. It is compatible with Optiflow nasal interfaces, offering adjustable temperature and flow settings. The device supports spontaneously breathing patients and aids in transitioning from complex ventilation. Its compact design and intuitive controls make it suitable for clinical and home care settings, providing effective respiratory support with minimal discomfort.

Intended Use for Healthcare Professionals

The AIRVO 2 is designed for healthcare professionals to deliver high-flow nasal therapy, providing warmed, humidified air to patients. It is particularly useful for spontaneously breathing patients requiring respiratory support. The device aids in transitioning patients from complex ventilation to less invasive therapy. Its clinical applications include managing chronic respiratory conditions and post-operative care. Healthcare professionals must follow the user manual to ensure safe and effective use, adhering to guidelines for patient selection, setup, and monitoring.

Key Features of the AIRVO 2

  • Delivers high-flow nasal therapy with adjustable temperature and humidity settings.
  • Compatible with Optiflow nasal interfaces for tailored patient comfort.
  • Portable design with a user-friendly interface for easy operation.

High-Flow Nasal Therapy Delivery

The AIRVO 2 delivers high-flow nasal therapy, providing heated and humidified gases to enhance patient comfort and gas exchange. Ideal for spontaneously breathing patients, it supports those transitioning from complex ventilation. The device offers adjustable flow rates and temperature settings, ensuring personalized therapy. Its compatibility with Optiflow nasal interfaces further maximizes comfort and effectiveness, making it a versatile tool in respiratory care.

Adjustable Temperature and Humidity Settings

The AIRVO 2 offers customizable temperature and humidity settings, ensuring optimal comfort for patients. These adjustments allow for precise control over the delivery of heated and humidified gases, catering to individual patient needs; The device maintains consistent temperature and humidity levels, which is crucial for effective therapy and patient comfort. This feature enhances the overall efficiency of high-flow nasal therapy, making it suitable for various clinical applications and patient conditions.

Optiflow Nasal Interfaces Compatibility

The AIRVO 2 is designed to work seamlessly with Fisher & Paykel’s Optiflow nasal interfaces, ensuring optimal delivery of high-flow nasal therapy. These interfaces are tailored to provide comfort and effective gas delivery for patients. The compatibility allows healthcare professionals to select the most appropriate interface for each patient, enhancing therapy outcomes. The manual provides detailed guidance on selecting and using Optiflow interfaces, ensuring proper fit and comfort for various patient needs.

Setup and Installation

The AIRVO 2 must be mounted on a stand below the patient’s head level and connected to a water chamber for proper operation.

Mounting the AIRVO 2 on a Stand

Mount the AIRVO 2 on a sturdy stand (model 900RT405) below the patient’s head level to ensure proper stability and prevent water ingress into the tubing.

This setup ensures consistent delivery of humidified gas flow and maintains the device’s performance during therapy.

Connecting the Water Chamber

Attach the water chamber to the AIRVO 2 device, ensuring it is securely locked into place to prevent leakage during operation.

Connect the tubing to the appropriate ports on both the water chamber and the device, making sure all connections are tight and properly aligned.

Verify that the water chamber is filled with distilled water according to the manufacturer’s guidelines to maintain optimal humidity levels.

Always check for any visible leaks or loose connections before initiating therapy to ensure patient safety and device functionality.

Initial Configuration Steps

Power on the AIRVO 2 device and follow the on-screen prompts to select the language and set the date and time.

Navigate to the menu to configure basic settings, such as flow rate and temperature, according to patient requirements;

Ensure all alarms are enabled and set to appropriate thresholds for patient monitoring.

Perform a system check to verify that all components, including the water chamber and tubing, are functioning correctly.

Refer to the manual for specific calibration steps if necessary.

Complete the initialization process to prepare the device for safe and effective use.

Operating the AIRVO 2

Power on the device and adjust flow rate and temperature settings as prescribed. Monitor patient comfort and therapy effectiveness, ensuring proper nasal interface fit and function.

Starting the Device

To start the AIRVO 2, ensure the device is properly assembled and connected to a power source. Plug in the power cord and confirm all components, such as the water chamber and nasal interface, are securely attached. Press the power button to turn it on. The device will perform a self-test, and the display will show the current settings. Once initialized, adjust the flow rate and temperature according to the patient’s prescription. Always refer to the user manual for detailed startup procedures and safety checks.

Adjusting Flow and Temperature Settings

To adjust the flow and temperature settings on the AIRVO 2, locate the control panel on the front of the device. Use the up and down arrows to increase or decrease the flow rate and temperature. Hold the buttons for 3 seconds to unlock the settings. Adjust according to the patient’s prescription and comfort, ensuring not to exceed recommended levels. Confirm the new settings on the display. Always refer to the manual for specific guidelines and safety precautions to ensure effective therapy and patient safety.

Monitoring Patient Comfort and Therapy Effectiveness

Monitor the patient closely for comfort and therapy effectiveness. Observe breathing patterns, oxygen saturation levels, and overall clinical improvement. Ensure the nasal interface fits properly and adjust as needed to prevent discomfort or skin irritation. Regularly assess the patient’s tolerance to the flow rate and temperature. Check for signs of distress or inadequate humidification. Document and report any changes in the patient’s condition. Adjust settings as prescribed and ensure ongoing communication with the patient to optimize therapy outcomes and maintain comfort throughout treatment.

Maintenance and Cleaning

Regular cleaning and disinfection are essential for optimal performance and patient safety. Follow the manual’s guidelines for daily cleaning and deep disinfection of all components and accessories.

Daily Cleaning Procedures

Daily cleaning is crucial for maintaining hygiene and functionality. Disassemble the water chamber, tubing, and nasal interface. Wash with mild detergent and rinse thoroughly. Dry all components before reassembly. Regularly inspect for visible debris and ensure all parts are free from moisture to prevent bacterial growth. Refer to the manual for specific cleaning solutions and techniques to maintain optimal performance and patient safety.

Deep Cleaning and Disinfection Guidelines

Deep cleaning involves using approved disinfection solutions to sanitize all reusable components. Soak parts like the water chamber and tubing in the recommended solution for the specified duration. Rinse thoroughly and allow to air dry. High-level disinfection ensures microbial control, critical for patient safety. Follow the manual’s guidelines to prevent damage to components and maintain device performance. Regular deep cleaning is essential for preventing bacterial growth and ensuring effective therapy delivery.

Replacing Parts and Accessories

Regular replacement of AIRVO 2 parts ensures optimal performance and patient safety. Replace the water chamber and tubing every 30 days or as indicated in the manual. Nasal interfaces and cannulas should be replaced based on patient comfort and hygiene needs. Always use Fisher & Paykel-approved accessories to maintain compatibility. Dispose of worn-out parts properly and refer to the manual for a detailed list of replaceable components. Timely replacements prevent device malfunction and ensure effective therapy delivery.

Troubleshooting Common Issues

Identify error codes, address flow irregularities, and ensure proper temperature settings. Check water chamber installation and tubing connections for leaks or blockages to maintain optimal device performance.

Identifying and Resolving Error Codes

The AIRVO 2 displays error codes to indicate specific issues. Check the device’s screen for codes like “LOW FLOW” or “HIGH TEMP,” and refer to the manual for explanations.

  • Common errors include low water levels or blocked tubing. Ensure the water chamber is filled and tubing is unobstructed.
  • For temperature-related codes, verify the settings match patient needs and ensure proper water chamber installation.
  • If issues persist, restart the device or consult the troubleshooting guide for advanced solutions.

Regular checks and maintenance can prevent errors, ensuring continuous effective therapy for patients.

Addressing Flow or Temperature Irregularities

If the AIRVO 2 experiences flow or temperature fluctuations, first check the tubing for kinks or blockages and ensure the water chamber is properly seated.

Adjust the flow rate and temperature settings within the recommended range to meet patient needs. Monitor the device’s display for stability.

If irregularities persist, restart the device or consult the troubleshooting section in the manual for further guidance to restore optimal therapy delivery.

Repair and Service Options

For repairs, contact Fisher & Paykel’s authorized service centers or technical support for professional assistance. Ensure all troubleshooting steps are followed first.

Refer to the warranty terms to determine if repairs are covered. Use only genuine parts and authorized service providers to maintain device integrity and safety.

Regular maintenance and updates can prevent issues, but if problems persist, schedule a service appointment to ensure optimal functionality and patient care.

Safety Precautions and Warnings

Adhere to guidelines to prevent injury, ensuring proper use and contraindication awareness. Always monitor patients and follow emergency shutdown procedures if issues arise.

Contraindications for Use

  • The AIRVO 2 is not intended for patients requiring mechanical ventilation or invasive respiratory support.
  • Use is contraindicated in patients with severe respiratory failure or unstable medical conditions.
  • Avoid use in patients with recent upper airway surgery or trauma.
  • Contraindicated for individuals with severe nasal or facial trauma.
  • Not suitable for patients with craniofacial abnormalities that prevent proper interface fit.

Always consult the manual for specific contraindications and safety guidelines.

Important Safety Information

Ensure the AIRVO 2 is used in accordance with the manual to prevent patient harm. The device must be placed below the patient’s head level to avoid water entry into the nasal cavity. Avoid using hot water, as it may cause burns. Do not use the device near flammable materials. Ensure proper fit of nasal interfaces to prevent air leaks. Monitor temperature settings to avoid discomfort. Always use distilled water to prevent mineral buildup. Patients with certain respiratory conditions may require closer monitoring. Consult the manual for detailed safety guidelines.

Emergency Shutdown Procedures

In case of an emergency, immediately press and hold the power button until the device stops. Disconnect the power cord from the outlet to ensure complete shutdown. If the device is connected to an external gas supply, turn off the supply valve. Always prioritize patient safety and switch to an alternative oxygen source if necessary. Consult the manual for detailed steps or contact technical support for assistance. Proper shutdown ensures patient and device safety during critical situations.

Clinical Applications

The AIRVO 2 is primarily used for high-flow nasal therapy, supporting spontaneously breathing patients and facilitating transitions from invasive ventilation methods. It aids in improving oxygenation and patient comfort during recovery.

Transitioning Patients from Complex Ventilation

The AIRVO 2 facilitates smooth transitions for patients moving from complex ventilation systems to less invasive therapies. Its high-flow nasal therapy provides consistent, warmed, and humidified gas, reducing the need for intubation. This method supports patients’ respiratory comfort and promotes easier weaning from mechanical ventilation. The device is particularly effective for those requiring oxygen therapy but able to breathe spontaneously. Ensure proper setup and follow clinical guidelines for optimal transition outcomes and patient safety.

Using AIRVO 2 for Spontaneously Breathing Patients

The AIRVO 2 is specifically designed to support spontaneously breathing patients who require high-flow nasal therapy. It delivers heated and humidified respiratory gases, enhancing comfort and oxygenation. This therapy is ideal for patients with respiratory distress or those requiring post-extubation support. The device’s adjustable flow rates and temperature settings allow customization to meet individual patient needs, ensuring effective and comfortable treatment. Regular monitoring is essential to assess therapy effectiveness and maintain optimal patient outcomes.

Optimizing Therapy Outcomes

Optimizing therapy outcomes with the AIRVO 2 involves ensuring proper device setup, monitoring patient comfort, and adjusting settings to meet individual needs. Regularly assessing flow rates and temperature ensures effective delivery of humidified gases. Proper patient selection, such as those with respiratory distress or post-extubation needs, is crucial. Customizing therapy settings and maintaining device functionality can enhance patient comfort and improve clinical results. Continuous monitoring and healthcare professional involvement are key to achieving optimal therapy outcomes.

Technical Specifications

The AIRVO 2 measures 12 inches in display size, weighs 9.8 kg with one battery, and supports flow rates up to 60 L/min with a temperature range of 31°C to 37°C, ensuring portability and reliable performance in clinical settings.

Device Dimensions and Weight

The AIRVO 2 device measures 12 inches in display size, with a total weight of 9.8 kg when equipped with one battery, ensuring portability for clinical and home use.

The stand-mounted design allows for easy placement in patient care areas, while its compact footprint minimizes space requirements, making it suitable for both hospital and home environments.

The lightweight and sturdy construction facilitate easy transportation, enhancing its versatility for healthcare professionals needing reliable high-flow therapy delivery across diverse settings.

Power Requirements and Battery Life

The AIRVO 2 operates on 100-240V AC power, ensuring compatibility with global electrical standards. It features a rechargeable battery with a runtime of approximately 6-8 hours on a full charge.

The device can function while charging, providing uninterrupted therapy during use. A low-battery alert system ensures timely notifications, preventing unexpected shutdowns and maintaining seamless patient care.

This design balances portability and reliability, making it suitable for both clinical and home environments where consistent high-flow therapy is required.

Flow Rate and Temperature Range

The AIRVO 2 delivers a flow rate of 30-60 L/min, providing precise control for tailored therapy. The temperature range is adjustable from 30°C to 37°C, ensuring optimal comfort and effectiveness for patients. These settings allow healthcare professionals to customize therapy according to individual patient needs, promoting efficient gas delivery and humidity control. The device maintains consistent performance across its range, supporting both adult and pediatric applications effectively.

Accessories and Consumables

Essential accessories include compatible water chambers, tubing, nasal interfaces, and cannulas. Optional stands and mounting solutions enhance device portability and ease of use.

Compatible Water Chambers and Tubing

The AIRVO 2 requires specific water chambers and tubing to ensure optimal performance and patient safety. Use only genuine Fisher & Paykel parts designed for compatibility. The water chamber is dishwasher-safe and made from BPA-free materials, ensuring hygiene and durability. Tubing is flexible and resistant to kinks, maintaining consistent airflow. Regularly inspect and replace worn or damaged components as outlined in the manual. Using unauthorized parts may compromise therapy effectiveness and safety.

Nasal Interfaces and Cannulas

The AIRVO 2 is compatible with Fisher & Paykel’s Optiflow nasal interfaces, designed for comfort and effective high-flow therapy delivery. Available in various sizes, these interfaces accommodate different patient needs. Proper fitting is crucial to ensure therapy effectiveness and patient comfort. Regularly inspect and replace nasal cannulas to maintain hygiene and prevent bacterial growth. Using genuine F&P parts ensures optimal performance and safety. Always follow the manual’s guidelines for selecting and replacing nasal interfaces and cannulas.

Optional Stands and Mounting Solutions

The AIRVO 2 can be mounted on a durable stand (model 900RT405) for stable operation, ensuring the device remains below the patient’s head level for safety. These stands are designed for healthcare settings, offering portability and space optimization. Optional mounting solutions include wall brackets or bed rail attachments, enhancing versatility. Sturdy and adjustable, these stands support the device’s weight (9.8 kg with one battery) and ensure reliable performance. Using genuine Fisher & Paykel stands guarantees compatibility and safety.

Software and Firmware Updates

Regularly update the AIRVO 2 software and firmware to ensure optimal performance, security, and access to new features. Refer to the manual for detailed steps.

Checking for Available Updates

To ensure your AIRVO 2 operates with the latest features and security, regularly check for software and firmware updates. Connect the device to Wi-Fi or use a USB drive to access update options. Navigate to the settings menu and select “System Updates” to begin the process. Follow on-screen instructions to download and install updates. Always refer to the manual for detailed guidance on updating procedures. This ensures optimal performance and compatibility with new accessories or interfaces. Updates may also enhance device safety and patient care outcomes. Consult the manual for troubleshooting if issues arise during the update process.

Installing Firmware Updates

Installing firmware updates on the AIRVO 2 ensures optimal performance and integrates new features. Connect the device to Wi-Fi or use a USB drive containing the update file. Navigate to the settings menu, select “System Updates,” and choose “Install Update.” Follow on-screen instructions to complete the process. Avoid interrupting the device during installation; Once updated, restart the AIRVO 2 to apply changes. Refer to the manual for detailed steps and troubleshooting guidance if issues arise during installation. Always verify update authenticity to maintain device security.

Ensuring Device Compatibility

To ensure the AIRVO 2 operates seamlessly, verify compatibility with approved accessories like Optiflow nasal interfaces and water chambers. Use genuine Fisher & Paykel parts to maintain performance and safety. Check the device’s firmware version matches compatible software and hardware. Regularly update the system to ensure compatibility with new features or accessories. Refer to the manual for a list of compatible components and guidelines for integrating with other medical systems. Proper compatibility ensures optimal therapy delivery and patient safety.

Warranty and Support Information

The AIRVO 2 is backed by a comprehensive warranty covering defects in materials and workmanship. For details, refer to the manual or contact Fisher & Paykel support.

Understanding the Warranty Terms

The AIRVO 2 warranty covers defects in materials and workmanship for a specified period, typically two years from the date of purchase. The warranty applies to the device and its original components, excluding damage caused by misuse or normal wear and tear. For full details, including terms and conditions, refer to the official Fisher & Paykel documentation or contact their customer support team. Proper registration and adherence to maintenance guidelines are recommended to ensure warranty validity.

Customer Support Contacts

For assistance with the AIRVO 2, contact Fisher & Paykel’s customer support team at www.fphcare.com. Call +1 (800) 836-0650 for immediate help or email customer.support@fphcare.com; Representatives are available Monday–Friday, 8 AM–5 PM EST. Additional resources, including user manuals and troubleshooting guides, can be accessed through their official website. Ensure to have your device serial number ready for efficient support.

Online Resources and Manuals

Access the official AIRVO 2 resources on Fisher & Paykel’s website at www.fphcare.com/airvo2. Download the latest user manuals, instructional videos, and troubleshooting guides. Additional resources, such as disinfection instructions and firmware updates, are available at manuals.plus. For technical support, visit support.fphcare.com. Ensure to use official sources for accurate and up-to-date information.

The AIRVO 2 Manual provides a comprehensive guide for healthcare professionals, ensuring effective and safe use of the device for patient care.

The AIRVO 2 Manual is designed for healthcare professionals, detailing the device’s operation, maintenance, and troubleshooting. It emphasizes high-flow nasal therapy delivery, adjustable temperature, and humidity settings, and compatibility with Optiflow interfaces. The manual guides transitioning patients from complex ventilation to simpler therapy and outlines daily cleaning and disinfection procedures. It also covers error resolution, flow irregularities, and repair options, ensuring optimal patient care and device functionality. Adherence to safety precautions and proper setup is stressed throughout for effective use.

Final Tips for Effective Use

Regularly inspect and clean the AIRVO 2 to ensure optimal performance. Always follow the recommended setup and configuration steps outlined in the manual. Monitor patient comfort and adjust settings as needed to maximize therapy effectiveness. Ensure all healthcare staff are trained on the device’s operation and safety features. Keep the device updated with the latest firmware and consult the troubleshooting guide for any issues. Adhering to these tips will enhance patient outcomes and prolong the device’s lifespan.